Form No: MM0214A / MM0215A
W
ater-Co
oled
Air-Conditioner
Single Package
with Scoll Compressors
Products That Perform . . .By People Who Care
®
50 / 60 Hz
R22 / R407C
WCPS-B Series
Vue de la page 0
1 2 3 4 5 6 ... 29 30

Résumé du contenu

Page 1 - R22 / R407C

Form No: MM0214A / MM0215AWater-CooledAir-ConditionerSingle Packagewith Scoll CompressorsProducts That Perform . . .By People Who Care®50 / 60 HzR22 /

Page 2 - TABLE OF CONTENTS

3.0 INSTALLATION3.4 UNPACKING AND UNCRATINGUnless specified, the units are generally not wooden crated. Only light packaging with woodenskid and wrapp

Page 3 - 1.0 INTRODUCTION

3.0 INSTALLATIONFIGURE 3.5.1: BLOWER DISCHARGE PATTERN1. WCPS 68B to 570BPATTERN NO: 1 PATTERNNO: 2PATTERNNO: 3PATTERNNO: 42. WCPS 640B to 1520BPATTER

Page 4 - 2.0 GENERAL INFORMATION

3.0 INSTALLATIONFIGURE 3.5.2 SUGGESTED METHOD FOR CONNECTING SUPPLY DUCTModel A B68-160 40 25190-510 60 35570-1520 80 503.6 EVAPORATOR SECTION1.) For

Page 5

3.0 INSTALLATION3.7 CONDENSER SECTION1.) All internal condenser water piping is completely factory assembled and pressure tested at300 psig for leakag

Page 6

3.0 INSTALLATIONFIGURE 3.8A: COOLING TOWER WATER PIPING SCHEMATICFigure 3.8B shows the suggested wiring arrangement necessary to interconnect the unit

Page 7

4.0 OPERATION4.1 SYSTEM CAPACITYAn accurate load calculation is essential because selection of units is based on the requiredtotal and sensible load a

Page 8

4.0 OPERATION4.4 TEMPERATURE SETTINGNormally the temperature setting for,a.) Cooling is 75-80°Fb.) Heating is 70°F ( If heating coil is available ).4.

Page 9

15316174279111415861310OUTINAIR OFFCOILRETURN AIR18124.0 OPERATION4.8 REFRIGERANT CIRCUIT AND COMPONENTSFIGURE 4.8: TYPICAL REFRIGERANT PIPING AND COM

Page 10 - 3.0 INSTALLATION

CHECK FUSE, START SIGNAL, SWITCHES,OVERLOAD RELAY, KEY SWITCH AND INTERLOCKINGAUTO STARTPUSH START BUTTON (BLOWER FAN)OVERLOAD RELAY AND SAFETY INTERL

Page 11

4.0 OPERATION4.10 START- UP CHECK LISTDUNHAM-BUSH INDUSTRIES SDN BHDLot 5755-6, Kidamai Industrial Park, Bukit Angkat,43000 Kajang, Selangor Darul E

Page 12

TABLE OF CONTENTSMANUAL INDEX PAGE1.0 INTRODUCTION...

Page 13

4.0 OPERATION4.11 TYPICAL WIRING SCHEMATIC WITHOUT STARTER4.12 TYPICAL WIRING SCHEMATIC WITH DOL

Page 14

4.0 OPERATION4.13 TYPICAL WIRING SCHEMATIC WITH AUTOTRANS

Page 15 - 4.0 OPERATION

5.0 MAINTENANCE5.1 GENERALAs with all mechanical equipment's, a program of regular inspection, cleaning and preventivemaintenance by trained pers

Page 16

5.0 MAINTENANCEcould indicate potential imminent breakdowns. Essential system parametersincludes discharge head pressure, saturated suction pressure,

Page 17

5.0 MAINTENANCEThis cleaning can be done mechanically or chemically. In chemical cleaning, a causticsolution is pumped through the heat exchanger, whi

Page 18

5.0 MAINTENANCE5.6 PULLEY ALIGNMENT1.) Insert one end of the string inside the gap between belt and pulley.2.) Rotate the pulley so that string is cli

Page 19

5.0 MAINTENANCEFigure 5.7: Belt Span6.) Compare the force you have applied with the values in table 5.7B.Note: A new drive should be tensioned to the

Page 20

LOW SUCTIONPRESSURESIGHTGLASSEVAPORATOR AIR FLOWEVAPORATOR AIRINLET TEMPERATURECLOGGED LIQUID FILTER DRIERLOW REFRIGERANT CHARGERESTRICTED LIQUID LINE

Page 21

INSUFFICIENTCOOLINNGTHERMOSTATHIGH DISCHARGEPRESSURERETURN AIRTEMPERATURESTOP VALVES INDISCHARGE LINECONDENSER WATERINLET TEMPERATURETOO HIGHFAULTY EL

Page 22 - 5.0 MAINTENANCE

NO COOLINGUNIT POWERSUPPLYFUSE FOR EVAP.CIRCUITCOMPRESSORCONTACTORTHERMOSTATEVAPORATORFAN MOTOROVERCURRENT RELAYFOR EVAP.FANCONDENSERPRESSURESWITCHOVE

Page 23

1.0 INTRODUCTIONThis equipment is factory manufactured and tested water-cooled package for thepurpose of air-conditioning. It consists mainly of a dir

Page 24

5.0 MAINTENANCE5.9 SAMPLE LOG SHEET SHEET NO...DUNHAM-BUSH WATER COOLED PACKAGE UNITUNIT MODEL NO. ...

Page 25

2.0 GENERAL INFORMATION2.1 SAMPLE NOMENCLATURE6 WCP S 640 B Q P2.2 RECEIVING, INSPECTION AND PACKAGINGAs soon as the unit is received, it should be i

Page 26

2.0 GENERAL INFORMATION2.) Supply air plenum.3.) Return air grille and integral filter frame.4.) Hot water heating coils or electric reheaters.5.) Com

Page 27

MIN 8"CONCRETEPLINTHFLOATINGPLINTHFLOORWCPS-BCORKSHEETFLOORWCPS-B3.0 INSTALLATION3.1 FOUNDATIONThe unit shall be placed on a flat, level, solid f

Page 28

1"6-1/2"2" DEFLECTIONSPRINGISOLATORSFACTORY PROVIDEDMOUNTING BRACKETSNON-SKIDNEOPRENE PADFLOORWCPS-B3.0 INSTALLATIONiii.) Support the c

Page 29

3.0 INSTALLATIONFIGURE 3.3A: FOR UNITS WITH SINGLE SIDE RETURN AIR, WCPS 68B TO 570BSide RecommendedMinimumClearanceRemark1.) Return air, front 48&quo

Page 30 - 5.0 MAINTENANCE

3.0 INSTALLATIONFIGURE 3.3B: FOR UNITS WITH SINGLE SIDE RETURN AIR, WCPS 640B TO1520BSide RecommendedMinimumClearanceRemark1.) Return air, front 48&q